User Tools

Site Tools


integrations:octopus

Integration with NRCS Octopus

Integration with Octopus system is realized by means of interaction between MOS Agent on the Octopus side and MOS Gateway module on the Skylark side. The interaction is implemented using the MOS protocol version 2.8.5.

MOS Devices (MOS Agent)

The MOS Devices→Devices window displays the MOS devices configured in the NRCS system.

The main right-click or toolbar menu items:

Menu itemDescription
NewOpen a dialog box to add a new MOS device
EditEdit a previously created MOS device
Content syncAfter the configuration is complete and two-way connection is established, perform a one-time synchronization of the media database content with the catalog of MOS objects on the Octopus side. To do this, click the “Request mosListAll from the MOS device” button.
MOS objectsIf you see non-zero values in the Public and Private fields, this indicates that the media database content has been successfully synchronized with the Octopus MOS objects directory.
Resend active rundownsResends previously activated Running Orders for this device.

MOS Device Settings

Click “New” in the MOS Devices→Devices window to create a new MOS device that will allow Octopus and Skylark to be paired via the MOS protocol.

Below there is an example of how a MOS device can be configured to work with the MOS Gateway module.

The options that require customization are described in detail. The rest of the parameters are set to default values.

Basic

CustomizeDescription
mosIDThis field specifies the MOS Gateway identifier (the “MOS ID” field in the MOS Gateway settings).
ncsIDThis field specifies the NRCS system identifier. This identifier must be specified in the “NCS ID” field in the MOS Gateway settings.
NcsIDThis field specifies the NRCS system ID.
Version Specify 2.8.5 as the version of the MOS protocol that will be used for connection between devices.
Media hostIP address of the server where the MOS Gateway is running.
Media portin the “Lower Port” field in the MOS Gateway settings.
Rundown hostIP address of the server where MOS Gateway is running.
Rundown portThe port number specified in the “Upper Port” field in the MOS Gateway settings.
Rundown portThe port number specified in the “Upper Port” field in the MOS Gateway settings.
Octopus media portThe value must be equal to the value specified in the Media port field.
Octopus rundown portThe port number specified in the “Upper Port” field in the MOS Gateway settings.
Octopus rundown portThe value must be equal to the value specified in the Rundown port.
Octopus IP addressThe NRCS address to be specified in the “NCS Address” field in the MOS Gateway settings. Specify a usable IP address or leave the field blank to use the default value.

Stories

If you have more than one MOS Device in your system, you may have a situation where multiple MOS Devices receive a single Running Order at the same time. In this case you need to enable the “Send MOS objects that belong to other devices” option. Without this option enabled, the downloaded Running Orders may not have any items to display because they may have been previously associated with another MOS Device.

Rundowns

Select Refresh method = roCreate.

Prompting

Status

This tab configures the display of statuses in the Running Order received from the MOS Device.

For the “Accepts on-air status for” option, set the values:

  • Rundown
  • Story
  • Element
  • Subelement

In the table, create a new row for each status (the list of supported statuses is available in the MOS Gateway module description). In the State column, specify the name of the status as it is passed from the MOS Gateway (for example, READY). In the BG column, you can set the background color of the cell in the MOS column.

Channels

Set the Item channels and Item channels rules options if you want to distribute channels on the NRCS side. These settings can be skipped if you want the Skylark server to distribute clips to channels itself.

Lowres

CG Support

MOS objects

Be sure to disable the “objDur is in frames” option. If this option is left on, the values of the transferred durations will be doubled (durations are transferred in fields, not frames).

Placeholders

Enable “Allow MOS object creation” and “Use the <mosObjCreate> message” to allow Octopus to create empty clips in the Skylark media database.

MOS object groups

Activations

Plugins

Vizrt

EVS

Other

MOS Agent Service

After creating a new device, you need to make sure that the service of the created MOS agent is running

The Services menu also allows you to check the status of the MOS Agent.

Running Order View

From the Rundowns→Rundown→Name menu, select Running Order to display.

General view of the Running Order window.

Uploading Running Order

Use the “MOS→Activate” button to activate the upload of this Running Order.

Select the target MOS device that is paired with the Skylark MOS Gateway, and then click OK.

If everything is configured correctly, at this point you should see the name of the activated Rundown in the MOS Running Order display, and when selected, the Rundown items should be loaded into the player playlist.

MOS Activations

The MOS Devices→Activations window displays active Rundown items for MOS devices.

Selecting Columns in Running Order

Right-clicking on a column name in Running Order allows you to configure a custom display.

Make sure the MOS, Ready, and Duration columns are enabled and displayed.

Story Editor

Double-clicking on the Running Order line opens the history editor.

Through the right-click menu or the New button in the toolbar you can create new items (MOS objects) of the desired type.

Specify the desired name for the new MOS object of the Video type.

The “Browse” button allows you to see all objects available in the Skylark server's media database. Available after the initial synchronization is done (see Content sync).

The “Create on MYMOSID” button (the name of your MOS Device will be specified instead of MYMOSID) opens a dialog for creating a pasted clip in the Skylark server media database.

When you click OK, a request is made to the Skylark server.

If the request is successful, an object with the specified ID will be created. If such a MediaId already exists, the suffix “(New 1)” will be added.

When Attach Media is executed, the server's media database will pass the READY status and updated duration of the assert to NCRS.

The status and duration will also be visible in Running Order.

integrations/octopus.txt · Last modified: 2025/01/16 12:32 by 114.119.138.172

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki

Copyright © 2009-2025 Skylark Technology Inc.