hardware:vtr_cable_rs232_rs422
Unsoldering Cable for VTR Connection to Serial Port
The SL NEO server can control several (up to eight) tape-recorders by RS232/422 interfaces and SONY 9 Pin Remote Protocol, or by IEEE1394 (FireWire) interfaces. If the VTR control feature has been ordered and corresponding software settings have been implemented, a cable must be produced according to the set RS-232 or RS-422 interfaces and the tables below.
| VTR control cable: RS-422Moxa/RS-422VTR | |||
|---|---|---|---|
| DB9 MALE | DB9 FEMALE | ||
| SONY RS-422 9-pin VTR Remote Connector | SL NEO SERVER RS-422 Moxa Port | ||
| 1 | GND | 5 | GND |
| 2 | Tx-(A) | 4 | Rx-(A) |
| 3 | Rx+(B) | 2 | Tx+(B) |
| 7 | Tx+(B) | 3 | Rx+(B) |
| 8 | Rx-(A) | 1 | Tx-(A) |
| VTR control cable: RS-232/RS-422VTR | |||
|---|---|---|---|
| DB9 MALE | DB9 FEMALE | ||
| SONY RS-422 9-pin VTR Remote Connector | SL NEO SERVER RS-232 (onboard COM) Port | ||
| 2 | Tx-(A) | 2 | Tx+(B) |
| 1+3+4+6 | Rx+(B) | 5 | GND |
| 8 | Rx-(A) | 3 | Rx+(B) |
| 7+8 | |||
hardware/vtr_cable_rs232_rs422.txt · Last modified: 2020/01/14 08:24 by Dmitriy Sazhin