Table of Contents
Profanity Delay (Actions)
The information is relevant for version 2.9.34 and later.
Description of Profanity Delay Actions.
Set video stream
Switching the signal source or file source to the module input.
Parameters
- Param1 - input stream type
- FILE - file source.
- LIVE - signal from the software module.
- Param2 - file name, software module name.
Set format conversion
Sets the video conversion mode upon a mismatch of the input signal Aspect Ratio and the module settings.
Parameters
- Param1 - conversion mode. Possible values: scale, crop, box, letter.
- Param2 - AFD use flag. Possible values: true or false.
Set format
Setting the Aspect Ratio of the output signal of the module.
Parameters
- Param1 - Aspect Ratio. Possible values: 4:3 or 16:9.
Set delay
Turns on/off the module depending on the parameter.
Parameters
- Param1- controls turning on:
- 1, on, yes or true - starts the module (enables signal delay by the time equal to the Max Delay value). The delayed signal will appear at the module output after the Max Delay interval.
- 0, off, no or false - disables the delay. The signal appears at the module output with no delay.
Toggle delay
Switches the current mode to the opposite: on→off or off→on. Allows using one key to turn on/off the module.
Parameters
No parameters.
Add delay
Increases the current delay buffer. Added in version 2.9.27.
Parameters
- Param1 - the number of frames to add to the delay buffer.
Add delay start
Starts increasing the current delay buffer. Added in version 2.9.27.
Parameters
- Param1 - the number of frames to initially add to the delay buffer
Add delay stop
Drop delay
Reduces the current delay buffer. Added in version 2.9.27.
Parameters
- Param1 - the number of frames to delete from the delay buffer.
Drop delay start
Starts reducing the current delay buffer. Added in version 2.9.27.
Parameters
- Param1 - the number of frames to initially delete from the delay buffer.
Drop delay stop
Clear step
Replacement starts after a period equal to (Max Delay-Clear Step), where duration equals Clear Step.
Parameters
- Param1 - sound channel mask. Example: 1/2/6/7.
Clear all
Immediately turns on replacement with duration equal to the Max Delay value. Allows activating the replacement process if the operator missed the right moment.
Parameters
- Param1 - sound channel mask. Example: 1/2/6/7.
Clear start
Replacement starts after a period equal to (Max Delay-Clear Step) and is implemented with no time limits until the Clear Stop command arrives.
Parameters
- Param1 - sound channel mask. Example: 1/2/6/7.
Clear stop
Replacement stops after a period equal to Max Delay.
Parameters
No parameters.
Set Source
Assigns a signal source for the service. Allows assigning a different module’s output as a signal source.
Parameters
- Param1 - string with a new signal source. The string is specified in the format:
shm_pal://SERVICE
. For example:shm_pal://Capture_1